SLG 1

Commercial nitrogen cylinders are filled at a pressure of maximum 200 bar. Hydraulic accumulators with a precharge pressure exceeding 200 bar can therefore not be filled using these cylinders. With precharge pressures between 100 and 150 bar the potential of the nitrogen cylinders is poorly exploited.

The OLAER nitrogen chargin units allow better utilisation of the nitrogen cylinders and a charging of the accumulators at pressures of up to 400 bar.

The charging unit runs automatically and its precharge pressure is controlled by a contact pressure gauge.

Download PDF-File  OSP 762 - Accumulator accessories - Nitrogen charging unit SLG 1
Download PDF-File Bedienungsanleitung Stickstoffladegerät


Design

  • Integrated hydraulic unit
  • Contact pressure gauge
  • Electronic control unit including connecting cable
  • Air/oil cooler
  • Connecting hoses

Technical features

  • Flow rate: 3 l/min
  • Power consumption: 1.5 kW
  • Supply voltage: 230 V - 1 - 50 Hz
  • Current consumption: 10 A
  • Min. N2 inlet pressure: 35 bar
  • Max. N2 outlet pressure: 400 bar
  • Weight (oil-filled): 69 kg

Connections

SLG 2

Commercial nitrogen cylinders are filled at a pressure of maximum 200 bar. Hydraulic accumulators with a precharge pressure exceeding 200 bar can therefore not be filled using these cylinders. With precharge pressures between 100 and 150 bar the potential of the nitrogen cylinders is poorly exploited.

The OLAER nitrogen chargin units allow better utilisation of the nitrogen cylinders and a charging of the accumulators at pressures of up to 400 bar.

The charging unit runs automatically and its precharge pressure is controlled by a contact pressure gauge.

Download PDF-File  OSP 763 - Accumulator accessories - Nitrogen charging unit SLG 2

Design

  • Integrated hydraulic unit
  • Pressure reducer
  • Electronic control unit including connecting cable
  • Pressure intensifier
  • Air/oil cooler
  • Connecting hoses

Technical features

  • Flow rate: 3 l/min
  • Power consumption: 1.5 kW
  • Supply voltage: 230 V - 1 - 50 Hz
  • Current consumption: 10 A
  • Min. N2 inlet pressure : 35 bar
  • Max. N2 outlet pressure: 400 bar
  • Weight (oil-filled): 69 kg

Connections

SLG 3

Commercial nitrogen cylinders are filled at a pressure of maximum 200 bar. Hydraulic accumulators with a precharge pressure exceeding 200 bar can therefore not be filled using these cylinders. With precharge pressures between 100 and 150 bar the potential of the nitrogen cylinders is poorly exploited.

The OLAER nitrogen chargin units allow better utilisation of the nitrogen cylinders and a charging of the accumulators at pressures of up to 300 bar.

The SLG 3 will be connected on a nitrogen bottle. The nitrogen is driven as well as deliver medium. So not additional energy is necessary.

Download PDF-File  OSP 764 - Accumulator accessories - Ties unit Type SLG 3

Design

  • Nitrogen driven gas booster DLE 30-1-GG
  • Pressure regulator
  • Pressure switch
  • Relief valve
  • Connecting and filling hoses

Technical features

  • Flow rate: 3 l/min
  • Min. N2 inlet pressure: 35 bar
  • Max. N2 outlet pressure: 300 bar
  • Weight: 25 kg

Connections